summary
The hybrid harmonic filter (HHF) absorbs harmonics generated in six-pulse nonlinear loads of inverter, UPS, and elevator, and meets the limits of voltage distortion (Vthd) and current distortion (Ithd) of IEEE Std. 519 in preload area. The product reduces an inductor capacity to a half of existing band-pass filter, and a filter condenser capacity to 1/3. Therefore, it is an easy-to-install filter for six-pulse nonlinear load, securing cost effectiveness.
- Problems of harmonic
-
- Resonance of power system
- Loss and overvoltage trip of drive
- Trip of harmonic device and fuse cutting
- Application
-
- ① Application loads: UPS (uninterruptible power supply), Inverter, converter, elevator, AC/DC motor drive, fan, pump, induction heater
- ② Application systems: 220V/380V/440V , 3~1000 HP
- ③ Application places: factory, department store, information processing center, large shopping mall, communication equipment, large building, university, hospital
Product Features
-
- Acquired certificates
-
- Patent no. 038379, Hybrid harmonic filter
- New Excellent Product Certification NEP-2003-91(EM), harmonic filter using three-phase reactor (May 28, 2007 to May 27, 2010)
- Excellent Procurement Product no. 2004101 (Oct. 26, 2004 to Oct. 25, 2008)
- Patent no. 10-2036580, advanced three-phase nonlinear load input-side passive harmonic filter
- Satisfied specification of harmonic limits
-
- The voltage/current distortion factors generated by harmonic voltage/current, lower than standard harmonic limits
- Applicable domestic and foreign harmonic limits standards: KEPCO, IEEE-519(the US), AS-2279(Australia), BS G5(the UK)
- 20-40% reduction in line current loss (in preload)
- 3-5% power saving (in preload)
- Solved power quality problems
-
- Prevention of damage, lifespan shortening, and rated capacity reduction caused by transformer overheating
- Prevention of damage and capacity reduction caused by cable overheating
- Prevention of communication disturbance by the induction phenomenon of harmonic current
- Prevention of reactor/capacitor damage by harmonics
- Prevention of trip by the troubled circuit breaker or fuse
- Prevention of malfunction of precision and protective devices by harmonics
- Prevention of device damage by surge or overvoltage of system
- Unnecessary system analysis
-
If a filter that meets a specification is installed regardless of field survey and system simulation, it is possible to satisfy specification and standardization.
Installation Effects
-
- 20-40% reduction in line current loss
- 3-5% power saving
- Prevention of damage and capacity reduction caused by transformer overheating
- Prevention of damage and capacity reduction caused by cable overheating
- Prevention of communication disturbance by the induction phenomenon of harmonic current
-
- Prevention of reactor/capacitor damage by harmonics
- Prevention of trip by the troubled circuit breaker or fuse
- Prevention of malfunction of precision and protective devices
- Prevention of device damage by surge or overvoltage of system
-
(Before installation)
-
(After installation)
Product Specification
게시판 리스트
Type name |
Load capacity |
Enclosure dimension [mm] |
HP |
kW |
W |
D
|
H |
HHF38005 |
5 |
3.7 |
350 |
500 |
500 |
HHF38008 |
7.5 |
5.6 |
350 |
500 |
500 |
HHF38010 |
10 |
7.5 |
420 |
730 |
1000 |
HHF38015 |
15 |
11 |
420 |
730 |
1000 |
HHF38020 |
20 |
15 |
420 |
730 |
1000 |
HHF38025 |
25 |
19 |
600 |
900 |
1200 |
HHF38030 |
30 |
22 |
600 |
900 |
1200 |
HHF38040 |
40 |
30 |
600 |
900 |
1200 |
HHF38050 |
50 |
37 |
600 |
900 |
1200 |
HHF38060 |
60 |
45 |
600 |
900 |
1200 |
HHF38100 |
100 |
75 |
600 |
900 |
1200 |
HHF38150 |
150 |
112 |
900 |
900 |
2150 |
HHF38200 |
200 |
149 |
900 |
900 |
2150 |
HHF38400 |
400 |
198 |
900 |
900 |
2150 |
※ Rated voltage 220V and 440V products are provided. A product size can be different depending on an installation location or condition. Therefore, please make sure to check it before placing an order.
※ Parts can also be supplied. Therefore, it is possible to install them in existing or new panel.